Explosion protection for ATEX Zones 2 and 22 RFID-technology for needs-based protection against tampering Thermoplastic enclosure Suitable for mounting to profile systems Suitable for hinged and sliding guards Series-wiring Manual release
For doors that are flush with the door frame, the optional m
For glass and Makrolon doors, the optional mounting kit MS-A
As long as the actuating unit remains inserted in the soleno
Note, Relative humidity
non-condensing
non-icing
Time, duty cycle solenoid
100 %
Time, test pulse duration, maximum
1 ms
Time, test pulse interval, solenoid control, minimum
40 ms
Selection (Yes/No), Manual release
Yes
Type of execution, mounting, Screws
2x M6
Number, Actuating directions
1
Selection (Yes/No), CADENAS
Yes
Selection (Yes/No), Traceparts
Yes
Selection (Yes/No), Power to lock
Yes
Type of application, Relative humidity, maximum
93 %
Coding, general information
Universal coding
Current, consumption at 24V, magnet control
10 mA
Current, consumption at 24V, safety inputs
5 mA
Current, consumption, solenoid ON, average
200 mA
Current, consumption, solenoid ON, peak
350 mA / 200 ms
Current, Residual current, Fail-safe output, maximum
0.5 mA
Current, Required rated short-circuit current to EN 60947-5-1