Muting interface for use with MLC and ELC safety light curtains and MLD multiple light beam safety devices. Includes muting enable function, muting-timeout extension, and timing-controlled 2-sensor muting.
SKU
2110-549954
Manufacturer code
549954
Rail mounting possible
true
Voltage type (supply voltage)
DC
Supply voltage DC
24 - 24 V
SIL according to IEC 61508
3
Performance level according to EN ISO 13849-1
Level e
Width
60 mm
Height
38.3 mm
Depth
225 mm
Power consumption
3.6 W
Model
Basic device
Suitable for monitoring of emergency-stop circuits
false
Suitable for monitoring of valves
false
Suitable for monitoring of optoelectronic protection equipment
true
Suitable for monitoring of tactile sensors
false
Suitable for monitoring of magnetic switches
false
Suitable for monitoring of proximity switches
false
Evaluation inputs
Other
With start input
true
With muting function
false
With feedback circuit
true
Type of control voltage 1
AC
Number of outputs, safety related, undelayed, semiconductors
2
Number of outputs, safety related, delayed, semiconductors
0
Number of outputs, signalling function, delayed, semiconductors
0
Voltage type (operating voltage)
DC
Operating voltage DC
24 - 24 V
Rated switch current
0.38 A
Type of safety according to IEC 61496-1
None
Stop category according to IEC 60204
Other
With approval for BG BIA
false
With approval according to UL
false
Performance Level (PL)
e
Category
4
ISO Standard
EN ISO 13849-1
Most suitable applications
Muting applications in combination with safety light curtains and multiple light beam safety devices.
Ambient temperature, operation (°C)
-30 ... 60
Type of switch function
OSSDs
Number of switching inputs (pcs)
8
Number of safety-related switching outputs (OSSDs) (pcs)