Type of Execution, Degree of pollution IEC/EN 60664-1
2
Type of Execution, IP Protection class, Clearance
IP54
Type of Execution, IP Protection class, General
IP40
Type of Execution, IP Protection class, clips or terminals
IP20
Type of Execution, Mechanical life, minimum,
20000000 Operations
Type of execution, mounting
Snaps onto standard DIN rail to EN 60715
Type of Execution, Overvoltage category IEC/EN 60664-1
III
Depth, General
121 mm
Height, General
100 mm
Width, General
22.5 mm
Electrical data, Cable section, maximum
2.5 mm²
Electrical data, Conduction resistance, maximum
40 Ω
Electrical data, Contact resistance, maximum
0.1 Ω
Material, contacts, electrical
Ag-Ni 10 and 0.2 µm gold-plated
Housing material
Glass-fibre reinforced thermoplastic, ventilated
Standard, EMC rating
EMC-Directive
Standard, standards
EN IEC 60947-5-1
EN ISO 13849-1
EN IEC 60204-1
EN IEC 60947-5-3
BG-GS-ET-14
BG-GS-ET-20
EN IEC 62061
EN IEC 60947-5-5
EN IEC 60947-1
Note, contact resistance
in new state
Note, General
Inductive loads (e.g. contactors, relays, etc.) are to be su
Note, applications
Safety sensor
Guard system
Note, Wiring diagram
The wiring diagram is shown with guard doors closed and in d
Monitoring 1 guard door(s), each with a magnetic safety sens
The ISD tables (Intergral System Diagnostics) for analysis o
Expansion of enable delay time: The enable delay time can be
To secure a guard door up to PL d and Category 3
If one or two external relays or contactors are used to swit
Modification for 2 NC contacts: The safety monitoring module
Number, LED's
1
Number, NC contacts
2
Number, NO contacts
1
Number, Safety contacts
1
PIM maintenance status
Discharge "Online catalog"
PNV, standard, certificates
cULus
BG
Power, electrical consumption
5 W
Type of electric connection
Screw terminals M20 x 1.5
rigid or flexible
Review, Resistance to vibrations to EN 60068-2-6
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Review, restistance to shock
30 g / 11 ms
Safety parameters, Category, EN ISO 13849, Relay outputs
Selection (Yes/No), Integral System Diagnostics, status
Yes
Selection, (Yes/No), Wire breakage detection
Yes
Type of application, Terminal designation
IEC/EN 60947-1
Standard, climatic stress
EN 60068-2-3
BG-GS-ET-14
Tightening torque, torque, clips
0.6 Nm
Tolerance, operating voltage, DC, maximum
20 %
Tolerance, operating voltage, DC, minimum
-10 %
Voltage, Rated control voltage at DC, maximum
28.8 VDC
Voltage, Rated control voltage at DC, minimum
20.4 VDC
Voltage, rated operating voltage
24 VDC
Electrical data, Input signal, HIGH Signal "1"
10 … 30 VDC
Electrical data, Input signal, LOW Signal "0"
0 … 2 VDC
Electrical data, Input resistance at GND
4000 Ω
Hinweis, Delivery capacity
Phased-out product
Note, ISD, Fault
Failure of door contacts to open or close
Cross-wire or short-circuit monitoring of the switch connect
Interruption of the switch connections
Failure of the safety relay to pull-in or drop-out
Fault on the input circuits or the relay control circuits of
Note, ISD, General, Fehler
The following faults are registered by the safety monitoring
Web, Delivery notice (date until)
2023-12-31
Selection (Yes/No), Earth connection detection
Yes
Tolerance, operating voltage, AC, maximum
10 %
Tolerance, operating voltage, AC, minimum
-15 %
Electrical data, Cable section, minimum
0.25 mm²
Number, Signalling outputs
2
Number, semi-conductor outputs with signalling function, undelayed