Level 1: Reset without edge detection, Optional Automatic reset function, Level 2: Opener (NC) Opener (NC) Two-functions safety monitoring module (double evaluation) 2 x 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2) Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
SKU
4250116201938
Manufacturer code
101176209
Current, Switching capacity, Relay, (Auxiliary contacts), maximum
2 A
Current, Switching capacity, Safe relay outputs, maximum
The wiring diagram is shown with guard doors closed and in d
Relay outputs: Suitable for 2 channel control, for increase
The control recognises cross-short, cable break and earth le
Input level: the example shows a 2-channel control of an Eme
Automatic start (level 1): The automatic start is programmed
Number, LED's
6
Number, Safety contacts
4
PIM maintenance status
Discharge "Online catalog"
PNV, standard, certificates
cULus
Power, electrical consumption
4.4 W
Type of electric connection
Screw terminals M20 x 1.5
rigid or flexible
Review, Resistance to vibrations to EN 60068-2-6
10 ... 55 Hz, Amplitude 0.35 mm
Review, restistance to shock
10 g / 11 ms
Safety parameters, Mission time, Relay outputs
20 Year(s)
Safety parameter
EN IEC 61508
EN IEC 60947-5-1
Safety parameters, Stop-Category
0
SAP, basic quantity unit
Piece
SAP, EAN (European Article Number)
4250116201938
SAP, product group
Initial
SAP, gross weight
235.000 g
SAP, net weight
235.000 g
Indication, Operating state, LED
Position relay K2
Position relay K1
Internal operating voltage U<sub>i</sub>
Position relay K3