1 Signalling output Suitable for the signal processing of outputs with contact sensors Suitable for the signal processing of outputs with contact sensors 3 safety contacts, STOP 0 Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
SKU
4030661446561
Manufacturer code
101212415
Current, Switching capacity, Relay, (Auxiliary contacts), maximum
2 A
Current, Switching capacity, Safe relay outputs, maximum
The wiring diagram is shown with guard doors closed and in d
Monitoring 1 guard door(s), each with a magnetic safety sens
The feedback circuit monitors the position of the contactors
To secure a guard door up to PL e and Category 4
For 1-channel control, connect NC contact to S11/S12 and bri
Connect potential p-type outputs of safety light grids/curta
Switch setting: The cross-wire short detection function (fac
Number, LED's
4
Number, NC contacts
2
Number, Safety contacts
3
PIM maintenance status
Discharge "Online catalog"
PNV, standard, certificates
cULus
TÜV
Power, electrical consumption
1.8 W
Type of electric connection
Screw terminals M20 x 1.5
rigid or flexible
Review, Resistance to vibrations to EN 60068-2-6
10 ... 55 Hz, Amplitude 0.35 mm
Review, restistance to shock
30 g / 11 ms
Safety parameters, Mission time, Relay outputs
20 Year(s)
Safety parameter
EN IEC 61508
EN IEC 60947-5-1
Safety parameters, Stop-Category
0
SAP, basic quantity unit
Piece
SAP, EAN (European Article Number)
4030661446561
SAP, product group
Initial
SAP, gross weight
250.000 g
SAP, net weight
250.000 g
Indication, Operating state, LED
Position relay K2
Position relay K1
Internal operating voltage U<sub>i</sub>