SRB-E-301MC-CC Machine safety relay module

SRB-E-301MC-CC
Plug-in spring-cage terminal blocks with coding
1 Signalling contact
Suitable for applications up to Cat. 4
PL e und up to SIL 3
1 or 2 channel signal evaluation
Start
feedback circuit monitoring
Optionally with short-circuit recognition
3 safety contacts, stop category 0
  • SKU
    4030661511603
  • Manufacturer code
    103016932
  • Current, Switching capacity, Relay, (Auxiliary contacts), maximum
    1 A
  • Current, Switching capacity, Safe relay outputs, maximum
    6 A
  • Current, Switching capacity, Safe relay outputs, minimum
    10 mA
  • Current, Utilisation category AC-15, Safe relay outputs
    4 A
  • Current, Utilisation category DC-13, Safe relay outputs
    4 A
  • Type of Execution, Degree of pollution IEC/EN 60664-1
    2
  • Type of Execution, IP Protection class, Clearance
    IP54
  • Type of Execution, IP Protection class, General
    IP40
  • Type of Execution, IP Protection class, clips or terminals
    IP20
  • Type of Execution, Mechanical life, minimum,
    10000000 Operations
  • Type of execution, mounting
    Snaps onto standard DIN rails to IEC 60715
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    III
  • Depth, General
    115 mm
  • Height, General
    98 mm
  • Width, General
    22.5 mm
  • Electrical data, Cable section, maximum
    1.5 mm²
  • Electrical data, Conduction resistance, maximum
    40 Ω
  • Electrical data, Contact resistance, maximum
    0.1 Ω
  • Material, contacts, electrical
    Ag-Ni, self-cleaning, positive drive
  • Housing material
    Glass-fibre reinforced thermoplastic, ventilated
  • Standard, EMC rating
    EMC-Directive
  • Standard, standards
    EN IEC 60947-5-1
    EN ISO 13849-1
    EN IEC 60204-1
    EN IEC 60947-5-3
    EN IEC 62061
    EN IEC 60947-5-5
    EN IEC 60947-1
    EN IEC 61508
  • Note, contact resistance
    in new state
  • Note, applications
    Safety sensor
    Guard system
    Emergency-Stop button
    Pull-wire emergency stop switches
    Safety light curtain
    Safety light barriers
    hinged safety guard
  • Number, LED's
    5
  • Number, NC contacts
    2
  • PIM maintenance status
    Discharge "Online catalog"
  • Power, electrical consumption
    2.9 W
  • Type of electric connection
    rigid or flexible
    Cage clamp, plug-in
  • Review, Resistance to vibrations to EN 60068-2-6
    10 ... 55 Hz, Amplitude 0.35 mm
  • Review, restistance to shock
    30 g / 11 ms
  • Safety parameters, Category, EN ISO 13849, Relay outputs
    4
  • Safety parameters, Mission time, Relay outputs
    20 Year(s)
  • Safety parameter
    EN IEC 61508
    EN ISO 13849-1
    EN IEC 62061
  • Safety parameters, Performance Level, Relay outputs
    e
  • Safety values, PFH value; Relay outputs
    0.000000006 /h
  • Safety parameters, Safety Integrity Level (SIL), Relais outputs
    3
  • Safety parameters, Stop-Category
    0
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661511603
  • SAP, product group
    Initial
  • SAP, gross weight
    250.000 g
  • SAP, net weight
    250.000 g
  • Indication, Operating state, LED
    Position relay K2
    Position relay K1
    Internal operating voltage U<sub>i</sub>
    UB: Supply voltage on
  • Temperature, Ambient temperature[generated product variant]
    -25 ... +60 °C
  • Temperature, ambient temperature, maximum
    60 °C
  • Temperature, ambient temperature, minimum
    -25 °C
  • Temperature, storage and transport temperature,[generated product variant]
    -40 ... +85 °C
  • Temperature, storage and transport temperature, maximum
    85 °C
  • Temperature, storage and transport temperature, minimum
    -40 °C
  • Time, Drop-out delay in case of emergency stop, typically
    20 ms
  • Time, Drop-out delay in case of power failure, typically
    80 ms
  • Time, Frequency range
    50 Hz
    60 Hz
  • Time, Pull-in delay at automatic start, maximum, typically
    100 ms
  • Time, Pull-in delay at RESET, typically
    20 ms
  • Voltage, Rated control voltage at AC 50 Hz, maximum
    26.4 VAC
  • Voltage, Rated control voltage at AC 50 Hz, minimum
    20.4 VAC
  • Voltage, Rated control voltage at AC 60 Hz, maximum
    26.4 VAC
  • Voltage, Rated control voltage at AC 60 Hz, minimum
    20.4 VAC
  • Voltage, Rated impulse withstand voltage
    4 kV
  • Voltage, rated operating voltage
    24 VAC -15% / +10%
    24 VDC -15% / +20%, residual ripple max. 10 %
  • Voltage, rated operating voltage
    24 VAC
  • Voltage, Switching capacity, Relay (auxiliary contacts), maximum
    24 VDC
  • Voltage, Switching capacity, Safe relay outputs, maximum
    250 VAC
  • Voltage, Switching capacity, Safe relay outputs, minimum
    10 VDC
  • Voltage, type
    AC
    DC
  • Voltage, Utilisation category AC-15, Safe relay outputs
    230 VAC
  • Voltage, Utilisation category DC-13, Safe relay outputs
    24 VDC
  • Web Type
    Product range
  • Selection (Yes/No), Automatic reset function
    Yes
  • Selection (Yes/No), Short-circuit recognition
    Yes
  • Selection (Yes/No), Integral System Diagnostics, status
    Yes
  • Selection, (Yes/No), Wire breakage detection
    Yes
  • Type of application, Terminal designation
    IEC 60947-1
  • Standard, climatic stress
    EN 60068-2-78
  • Tolerance, operating voltage, DC, maximum
    20 %
  • Tolerance, operating voltage, DC, minimum
    -15 %
  • Voltage, Rated control voltage at DC, maximum
    28.8 VDC
  • Voltage, Rated control voltage at DC, minimum
    20.4 VDC
  • Voltage, rated operating voltage
    24 VDC
  • Selection (Yes/No), Earth connection detection
    Yes
  • Selection (Yes/No), Feedback circuit
    Yes
  • Tolerance, operating voltage, AC, maximum
    10 %
  • Tolerance, operating voltage, AC, minimum
    -15 %
  • Electrical data, Cable section, minimum
    0.25 mm²
  • Number, Auxiliary contacts
    1
  • Selection (Yes/No), Electronic Fuse
    Yes
  • Selection (Yes/No), Start input
    Yes
  • Power, electrical consumption
    5.0 VA
  • Safety parameters, Common Cause Failure (CCF), Relay outputs, minimum
    65
  • Selection (Yes/No), Removable Terminals
    Yes
  • Selection (Yes/No), EPLAN
    Yes
  • Safety parameters, Diagnostic Coverage (DC) Level, Relay outputs
    > 99 %
  • Time, Switching frequency, maximum
    0.3 Hz
  • Safety contacts, STOP 0
    3
  • Safety values, PFD value, Relay outputs
    0.00004