SETHT25CI-300F.HF/PX200M12 BTXDiffuse sensor with background suppression set
Diffuse sensor with background suppression, pre-mounted with a mounting system, featuring a permanently set range and suppression of HF illumination. Comes with either one or two digital switching outputs.
SKU
2110-50150373
Manufacturer code
50150373
Triangulation
Background fade-out
Pre failure notice
false
With time function
false
Max. output current
100 A
With reflector
false
Analogue output 0 V ... 10 V
false
Analogue output 0 mA ... 20 mA
false
Analogue output 4 mA ... 20 mA
false
Analogue output -10 V ... +10 V
false
With other analogue output
false
With communication interface analogue
false
With communication interface AS-Interface
false
With communication interface CANOpen
false
With communication interface DeviceNet
false
With communication interface Ethernet
false
With communication interface INTERBUS
false
With communication interface PROFIBUS
false
With communication interface RS-232
false
With communication interface RS-422
false
With communication interface RS-485
false
With communication interface SSD
false
With communication interface SSI
false
Number of semiconductor outputs with signalling function
1
Number of contact energized outputs with signalling function
0
Number of protected semiconductor outputs
0
Number of protected contact energized outputs
0
Type of electric connection
Cable with connector
Type of switching output
PNP
Type of switch function
Other
Operation agent-safety class
Safety class 3
Explosion safety category for gas
None
Explosion safety category for dust
None
Construction type housing
Cuboid
Width sensor
15 mm
Height of sensor
42.7 mm
Length of sensor
30 mm
Sensing mode
Dark switching
Material of optical surface
Plastic
Housing material
Plastic
Plastic
Plastic
Plastic
Max. output current at protected output
0 mA
Ambient temperature
-40 - 60 °C
Response time
0.33 s
Switching frequency
250 Hz
Switching voltage of OSSD at state "high"
0 V
Rated control supply voltage DC
10 - 30 V
Voltage type
DC
DC
DC
DC
With monitoring function downstream switching devices
false
Laser protection class
None
Wavelength of the sensor
850 nm
Type of light
Infrared light
With restart blockage
false
Suitable for safety functions
false
Degree of protection (IP)
Other
Setting procedure
Manual adjustment
Material of cable sheath
Polyurethane (PUR)
Operating distance
0 - 1300 mm
Adjustment range
50 - 1300 mm
Supply voltage
10 ... 30
Construction type housing
Cubic
Switching frequency
250
Ambient temperature, operation (°C)
-40 ... 60
Special version
Article set
Suppression of HF illumination (LED)
Permanently set range 300 mm
Most suitable applications
Detection tasks requiring background suppression and precise distance measurement.