Automatic reset function 2 safety contacts Suitable for signal processing of emergency stop control devices, interlocking equipment, etc
SKU
4030661544939
Manufacturer code
103037577
Type of application, Terminal designation
IEC/EN 60947-1
Type of Execution, Degree of pollution IEC/EN 60664-1
2
Type of Execution, IP Protection class, Clearance
IP54
Type of Execution, IP Protection class, General
IP40
Type of Execution, IP Protection class, clips or terminals
IP20
Type of Execution, Mechanical life, minimum,
10000000 Operations
Type of execution, mounting
Snaps onto standard DIN rail to EN 60715
Type of Execution, Overvoltage category IEC/EN 60664-1
III
Depth, General
121 mm
Height, General
100 mm
Width, General
22.5 mm
Electrical data, Conduction resistance, maximum
30 Ω
Electrical data, Contact resistance, maximum
0.1 Ω
Material, contacts, electrical
AgSn0. self-cleaning, positive drive
Housing material
Glass-fibre reinforced thermoplastic, ventilated
Standard, climatic stress
EN 60068-2-78
Standard, EMC rating
EMC-Directive
Note, contact resistance
in new state
Note, General
Inductive loads (e.g. contactors, relays, etc.) are to be su
Note, Wiring diagram
The wiring diagram is shown with guard doors closed and in d
Monitoring 1 guard door(s), each with a magnetic safety sens
If only one external relay or contactor is used to switch th
To secure a guard door up to PL e and Category 4
The feedback circuit monitors the position of the contactors
Automatic start: The automatic start is programmed by conne
Number, LED's
5
Number, NC contacts
2
Number, Safety contacts
2
PIM maintenance status
Discharge "Online catalog"
Review, Resistance to vibrations to EN 60068-2-6
10 ... 55 Hz, Amplitude 0.35 mm
Review, restistance to shock
30 g / 11 ms
Safety parameters, Category, Stop 0
4
Safety parameters, Common Cause Failure (CCF), Relay outputs, minimum