Already a member? Sign in or create an account

Cart

Product Quantity  

Your cart is empty.

PROTECT-IE-11-SK EX Machine safety accessory

PROTECT-IE-11-SK
Input for up to 4 sensors per interface e.g.: magnetic safety switches type BNS, emergency stop devices, interlocking devices and others
2 safety contacts
  • SKU
    4250116202232
  • Manufacturer code
    101189095
  • Type of application, Terminal designation
    IEC/EN 60947-1
  • Current, Switching capacity, Relay, (Auxiliary contacts), maximum
    0.1 A
  • Current, Switching capacity, Safe relay outputs, maximum
    2 A
  • Current, Switching capacity, Safe relay outputs, minimum
    10 mA
  • Current, Utilisation category DC-12, Digital output
    0.1 A
  • Current, Utilisation category DC-13, Safe relay outputs
    2 A
  • Type of Execution, Degree of pollution VDE 0110
    2
  • Type of Execution, IP Protection class, Clearance
    IP20
  • Type of Execution, IP Protection class, General
    IP20
  • Type of Execution, IP Protection class, clips or terminals
    IP20
  • Type of Execution, Mechanical life, minimum,
    10000000 Operations
  • Type of execution, mounting
    Snaps onto standard DIN rail to EN 60715
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    III
  • Depth, General
    61 mm
  • Height, General
    126 mm
  • Width, General
    48 mm
  • Electrical data, Cable section, maximum
    1.5 mm²
  • Electrical data, Cable section, minimum
    0.14 mm²
  • Electrical data, Conduction resistance, maximum
    40 Ω
  • Electrical data, Contact resistance, maximum
    0.1 Ω
  • Electrical data, Input signal, HIGH Signal "1"
    19 - 28,8 VDC
  • Electrical data, Input signal, LOW Signal "0"
    0 - 1 VDC
  • Electrical data, Input resistance at GND
    2900 Ω
  • Electrical data, Input resistance at Ue
    2900 Ω
  • Housing material
    Glass-fibre reinforced thermoplastic, ventilated
  • Standard, climatic stress
    EN 60068-2-78
  • Standard, EMC rating
    EMC-Directive
  • Standard, standards
    EN IEC 60947-5-1
    EN ISO 13849-1
    EN IEC 61508
    EN IEC 60204-1
    EN IEC 60947-5-3
    EN IEC 62061
    EN IEC 60947-5-5
    EN IEC 60947-1
  • Note, contact resistance
    in new state
  • Review, safety parameters
    for max. 36,500 switching cycles/year and max. 60% contact l
  • Note, applications
    Safety sensor
    Guard system
    Emergency-Stop button
    Pull-wire emergency stop switches
  • Number, Auxiliary contacts
    1
  • Number, LED's
    5
  • Number, NC contacts
    1
  • Number, NO contacts
    1
  • Number, Safety contacts
    2
  • Web, Delivery notice (date until)
    2024-12-31
  • PIM maintenance status
    Discharge "Online catalog"
  • PNV, standard, certificates
    cULus
  • Power, electrical consumption
    1.7 W
  • Type of electric connection
    Screw connection, plug-in
  • Review, Resistance to vibrations to EN 60068-2-6
    10...55 Hz, Amplitude 0.35 mm, ± 15 %
  • Review, restistance to shock
    30 g / 11 ms
  • Safety parameters, Category, EN ISO 13849, Relay outputs
    3
  • Safety parameters, Common Cause Failure (CCF), Relay outputs, minimum
    65
  • Safety parameters, Diagnostic Coverage (DC) Level, Relay outputs
    60 %
  • Safety parameters, Mission time, Relay outputs
    20 Year(s)
  • Safety parameter
    EN IEC 61508
    EN IEC 60947-5-1
  • Safety parameters, Performance Level, Relay outputs
    d
  • Safety values, PFH value; Relay outputs
    0.0000002 /h
  • Safety parameters, Safety Integrity Level (SIL), Relais outputs
    2
  • Safety parameters, Stop-Category
    0
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4250116202232
  • SAP, product group
    Initial
  • SAP, gross weight
    140.000 g
  • SAP, net weight
    140.000 g
  • Indication, Operating state, LED
    Position relay K3
    Position relay K3
    Position relay K2
    Position relay K1
  • Temperature, Ambient temperature[generated product variant]
    -25 ... +55 °C
  • Temperature, ambient temperature, maximum
    55 °C
  • Temperature, ambient temperature, minimum
    -25 °C
  • Temperature, storage and transport temperature,[generated product variant]
    -40 ... +85 °C
  • Temperature, storage and transport temperature, maximum
    85 °C
  • Temperature, storage and transport temperature, minimum
    -40 °C
  • Time, Drop-out delay in case of "emergency stop", maximum
    20 ms
  • Time, Pull-in delay at automatic start, maximum
    20 ms
  • Tolerance, operating voltage, DC, maximum
    20 %
  • Tolerance, operating voltage, DC, minimum
    -15 %
  • Voltage, Rated control voltage at DC, maximum
    28.8 VDC
  • Voltage, Rated control voltage at DC, minimum
    20.4 VDC
  • Voltage, Rated impulse withstand voltage
    0.8 kV
  • Voltage, rated operating voltage
    24 VDC -15% / +20%, residual ripple max. 10 %
  • Voltage, rated operating voltage
    24 VDC
  • Voltage, Switching capacity, Relay (auxiliary contacts), maximum
    24 VDC
  • Voltage, Switching capacity, Safe relay outputs, maximum
    24 VAC
  • Voltage, Switching capacity, Safe relay outputs, minimum
    10 VDC
  • Voltage, type
    DC
  • Voltage, Utilisation category DC-12, Digital output
    24 VDC
  • Voltage, Utilisation category DC-13, Safe relay outputs
    24 VDC
  • Web Type
    Product range
  • Selection (Yes/No), Automatic reset function
    Yes
  • Selection (Yes/No), Short-circuit recognition
    Yes
  • Selection (Yes/No), Earth connection detection
    Yes
  • Selection (Yes/No), Electronic Fuse
    Yes
  • Selection (Yes/No), Integral System Diagnostics, general
    Yes
  • Selection, (Yes/No), Wire breakage detection
    Yes
  • Selection (Yes/No), Removable Terminals
    Yes

Related products