MSI-RM2B-02
This safety relay is designed for signal conversion of electronic safety outputs on potential-free relay contacts. It features automatic restart and feedback path for EDM integration.
  • SKU
    2110-547955
  • Manufacturer code
    547955
  • Model
    Basic device
  • Rail mounting possible
    true
  • Type of electric connection
    Spring clamp connection
  • Voltage type (supply voltage)
    DC
  • Suitable for monitoring of emergency-stop circuits
    false
  • Suitable for monitoring of valves
    false
  • Suitable for monitoring of optoelectronic protection equipment
    true
  • Suitable for monitoring of tactile sensors
    false
  • Suitable for monitoring of magnetic switches
    false
  • Suitable for monitoring of proximity switches
    false
  • Evaluation inputs
    Other
  • Power consumption
    2.5 W
  • With start input
    true
  • With muting function
    false
  • With feedback circuit
    true
  • Type of control voltage 1
    AC
  • Number of outputs, safety related, undelayed, with contact
    2
  • Number of outputs, safety related, delayed, with contact
    0
  • Number of outputs, safety related, delayed, semiconductors
    0
  • Number of outputs, signalling function, undelayed, with contact
    1
  • Number of outputs, signalling function, delayed, semiconductors
    0
  • Voltage type (operating voltage)
    DC
  • Type of safety according to IEC 61496-1
    None
  • Stop category according to IEC 60204
    Other
  • Performance level according to EN ISO 13849-1
    Level e
  • SIL according to IEC 61508
    3
  • With approval for BG BIA
    false
  • With approval according to UL
    false
  • Width
    17.5 mm
  • Height
    111 mm
  • Depth
    114.1 mm
  • Supply voltage DC
    24 - 24 V
  • Number of outputs, safety related, undelayed, semiconductors
    2
  • Operating voltage DC
    24 - 24 V
  • Most suitable applications
    Signal conversion of electronic safety outputs on potential-free relay contacts
  • Ambient temperature, operation (°C)
    0 ... 50
  • Type of switch function
    2 NO contacts + 1 NC contact
  • Performance Level (PL)
    e
  • Category
    Up to 4 (depending on the category of the upstream protective device)
  • ISO Standard
    EN ISO 13849-1
  • Number of safety-related switching outputs (OSSDs) (pcs)
    2