This safety relay is designed for signal conversion of electronic safety outputs on potential-free relay contacts. It features automatic restart and feedback path for EDM integration.
SKU
2110-547955
Manufacturer code
547955
Model
Basic device
Rail mounting possible
true
Type of electric connection
Spring clamp connection
Voltage type (supply voltage)
DC
Suitable for monitoring of emergency-stop circuits
false
Suitable for monitoring of valves
false
Suitable for monitoring of optoelectronic protection equipment
true
Suitable for monitoring of tactile sensors
false
Suitable for monitoring of magnetic switches
false
Suitable for monitoring of proximity switches
false
Evaluation inputs
Other
Power consumption
2.5 W
With start input
true
With muting function
false
With feedback circuit
true
Type of control voltage 1
AC
Number of outputs, safety related, undelayed, with contact
2
Number of outputs, safety related, delayed, with contact
0
Number of outputs, safety related, delayed, semiconductors
0
Number of outputs, signalling function, undelayed, with contact
1
Number of outputs, signalling function, delayed, semiconductors
0
Voltage type (operating voltage)
DC
Type of safety according to IEC 61496-1
None
Stop category according to IEC 60204
Other
Performance level according to EN ISO 13849-1
Level e
SIL according to IEC 61508
3
With approval for BG BIA
false
With approval according to UL
false
Width
17.5 mm
Height
111 mm
Depth
114.1 mm
Supply voltage DC
24 - 24 V
Number of outputs, safety related, undelayed, semiconductors
2
Operating voltage DC
24 - 24 V
Most suitable applications
Signal conversion of electronic safety outputs on potential-free relay contacts
Ambient temperature, operation (°C)
0 ... 50
Type of switch function
2 NO contacts + 1 NC contact
Performance Level (PL)
e
Category
Up to 4 (depending on the category of the upstream protective device)
ISO Standard
EN ISO 13849-1
Number of safety-related switching outputs (OSSDs) (pcs)