AES 1185.3 24 VAC Machine safety relay module

AES 1185.3 24 VAC
Monitoring of BNS range magnetic safety sensors
1 safety contact, STOP 0
  • SKU
    4030661279442
  • Manufacturer code
    101131929
  • Current, Switching capacity, Relay, (Auxiliary contacts), maximum
    2 A
  • Current, Switching capacity, Safe relay outputs, maximum
    8 A
  • Current, Switching capacity, Safe relay outputs, minimum
    10 mA
  • Current, Thermal test current
    4 A
  • Current, Utilisation category AC-15, Safe relay outputs
    6 A
  • Current, Utilisation category DC-12, Digital output
    0.1 A
  • Current, Utilisation category DC-13, Safe relay outputs
    6 A
  • Type of Execution, Degree of pollution IEC/EN 60664-1
    2
  • Type of Execution, IP Protection class, Clearance
    IP54
  • Type of Execution, IP Protection class, General
    IP40
  • Type of Execution, IP Protection class, clips or terminals
    IP20
  • Type of Execution, Mechanical life, minimum,
    50000000 Operations
  • Type of execution, mounting
    Snaps onto standard DIN rail to EN 60715
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    III
  • Depth, General
    110 mm
  • Height, General
    75 mm
  • Width, General
    22.5 mm
  • Electrical data, Cable section, maximum
    2.5 mm²
  • Electrical data, Conduction resistance, maximum
    40 Ω
  • Electrical data, Contact resistance, maximum
    0.1 Ω
  • Material, contacts, electrical
    Ag-Ni, Au
  • Housing material
    Glass-fibre, reinforced thermoplastic
  • Standard, EMC rating
    EMC-Directive
  • Standard, standards
    EN IEC 60947-5-1
    EN ISO 13849-1
    EN IEC 60204-1
    EN IEC 60947-5-3
    BG-GS-ET-14
    BG-GS-ET-20
    EN IEC 62061
    EN IEC 60947-5-5
    EN IEC 60947-1
  • Note, contact resistance
    in new state
  • Note, General
    Inductive loads (e.g. contactors, relays, etc.) are to be su
  • Review, safety parameters
    for max. 50,000 switching cycles/year and max. 80% contact l
  • Note, applications
    Safety sensor
    Guard system
  • Note, Wiring diagram
    The wiring diagram is shown with guard doors closed and in d
    The ISD tables (Intergral System Diagnostics) for analysis o
    Expansion of enable delay time: The enable delay time can be
    To secure 3 guard doors up to PL d and Category 3
    Monitoring 3 guard door(s), each with a magnetic safety sens
    The feedback circuit monitors the position of the contactors
    Start push button: A start push button (NO) can optionally b
    If neither start button nor feedback circuit are connected,
    If only one external relay or contactor is used to switch th
  • Number, LED's
    1
  • Number, NC contacts
    3
  • Number, NO contacts
    3
  • Number, Safety contacts
    1
  • PIM maintenance status
    Discharge "Online catalog"
  • PNV, standard, certificates
    cULus
  • Power, electrical consumption
    5 W
  • Type of electric connection
    Screw terminals M20 x 1.5
    rigid or flexible
  • Review, Resistance to vibrations to EN 60068-2-6
    10...55 Hz, Amplitude 0.35 mm, ± 15 %
  • Review, restistance to shock
    30 g / 11 ms
  • Safety parameters, Category, EN ISO 13849, Relay outputs
    3
  • Safety parameters, Mission time, Relay outputs
    20 Year(s)
  • Safety parameter
    EN IEC 61508
    EN ISO 13849-1
  • Safety parameters, Performance Level, Relay outputs
    d
  • Safety values, PFH value; Relay outputs
    0.0000001 /h
  • Safety parameters, Safety Integrity Level (SIL), Relais outputs
    2
  • Safety parameters, Stop-Category
    0
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661279442
  • SAP, product group
    Initial
  • SAP, gross weight
    150.000 g
  • SAP, net weight
    150.000 g
  • Temperature, Ambient temperature[generated product variant]
    +0 ... +55 °C
  • Temperature, ambient temperature, maximum
    55 °C
  • Temperature, ambient temperature, minimum
    0 °C
  • Temperature, storage and transport temperature,[generated product variant]
    -25 ... +70 °C
  • Temperature, storage and transport temperature, maximum
    70 °C
  • Temperature, storage and transport temperature, minimum
    -25 °C
  • Time, Drop-out delay in case of emergency stop, typically
    20 ms
  • Time, Drop-out delay in case of power failure, typically
    80 ms
  • Time, Frequency range
    50 Hz
    60 Hz
  • Time, Pull-in delay at automatic start, maximum, typically
    100 ms
  • Time, Pull-in delay at RESET, typically
    20 ms
  • Voltage, Rated control voltage at AC 50 Hz, maximum
    26.4 VAC
  • Voltage, Rated control voltage at AC 50 Hz, minimum
    20.4 VAC
  • Voltage, Rated control voltage at AC 60 Hz, maximum
    26.4 VAC
  • Voltage, Rated control voltage at AC 60 Hz, minimum
    20.4 VAC
  • Voltage, Rated impulse withstand voltage
    4 kV
  • Voltage, rated operating voltage
    24 VAC -15% / +10%
    24 VDC -10%/+20%, residual ripple max. 10%
  • Voltage, rated operating voltage
    24 VAC
  • Voltage, Switching capacity, Relay (auxiliary contacts), maximum
    24 VDC
  • Voltage, Switching capacity, Safe relay outputs, maximum
    250 VAC
  • Voltage, Switching capacity, Safe relay outputs, minimum
    10 VDC
  • Voltage, type
    AC
  • Voltage, Utilisation category AC-15, Safe relay outputs
    230 VAC
  • Voltage, Utilisation category DC-12, Digital output
    24 VDC
  • Voltage, Utilisation category DC-13, Safe relay outputs
    24 VDC
  • Web Type
    Product range
  • Selection (Yes/No), Automatic reset function
    Yes
  • Selection (Yes/No), Short-circuit recognition
    Yes
  • Selection (Yes/No), Integral System Diagnostics, status
    Yes
  • Selection (Yes/No), Reset after disconnection of supply voltage
    Yes
  • Selection, (Yes/No), Wire breakage detection
    Yes
  • Type of application, Terminal designation
    IEC/EN 60947-1
  • Standard, climatic stress
    BG-GS-ET-14
    IEC 60947-5-3
  • Tightening torque, torque, clips
    0.6 Nm
  • Voltage, Rated control voltage at DC, maximum
    28.8 VDC
  • Voltage, Rated control voltage at DC, minimum
    20.4 VDC
  • Electrical data, Input signal, HIGH Signal "1"
    12 … 30 VDC
  • Electrical data, Input signal, LOW Signal "0"
    0 … 2 VDC
  • Electrical data, Input resistance at GND
    5000 Ω
  • Hinweis, Delivery capacity
    Phased-out product
  • Note, ISD, Fault
    Failure of door contacts to open or close
    Cross-wire or short-circuit monitoring of the switch connect
    Interruption of the switch connections
    Failure of the safety relay to pull-in or drop-out
    Fault on the input circuits or the relay control circuits of
  • Note, ISD, General, Fehler
    The following faults are registered by the safety monitoring
  • Number, inputs for NC
    3
  • Number, inputs for NO
    3
  • Web, Delivery notice (date until)
    2023-12-31
  • Selection (Yes/No), Earth connection detection
    Yes
  • Selection (Yes/No), Feedback circuit
    Yes
  • Tolerance, operating voltage, AC, maximum
    10 %
  • Tolerance, operating voltage, AC, minimum
    -15 %

Related products