Type of Execution, IP Protection class, clips or terminals
IP20
Type of Execution, Mechanical life, minimum,
20000000 Operations
Type of execution, mounting
Snaps onto standard DIN rail to EN 60715
Type of Execution, Overvoltage category IEC/EN 60664-1
III
Depth, General
121 mm
Height, General
100 mm
Width, General
45 mm
Electrical data, Cable section, maximum
2.5 mm²
Electrical data, Conduction resistance, maximum
40 Ω
Electrical data, Contact resistance, maximum
0.1 Ω
Material, contacts, electrical
Ag-Ni + Au
Housing material
Glass-fibre reinforced thermoplastic, ventilated
Standard, standards
EN IEC 60947-5-1
EN ISO 13849-1
EN IEC 60204-1
EN IEC 60947-5-3
BG-GS-ET-20
EN IEC 62061
EN IEC 60947-5-5
EN IEC 60947-1
Note, contact resistance
in new state
Note, General
Inductive loads (e.g. contactors, relays, etc.) are to be su
Note, applications
safe standstill monitoring
Note, Wiring diagram
The wiring diagram is shown with guard doors closed and in d
The ISD tables (Intergral System Diagnostics) for analysis o
To monitor one guard door at plants with dangerous run-on mo
Standstill monitoring for unlocking solenoid interlocks
The solenoid interlock can be opened, when the fail-safe sta
For suitable IFL range p-type inductive proximity switches,
Selection (Yes/No), Integral System Diagnostics, status
Yes
Selection (Yes/No), Reset after disconnection of supply voltage
Yes
Selection, (Yes/No), Wire breakage detection
Yes
Type of application, Terminal designation
IEC/EN 60947-1
Standard, climatic stress
EN 60068-2-3
BG-GS-ET-14
Tightening torque, torque, clips
0.6 Nm
Voltage, Rated control voltage at DC, maximum
253 VDC
Voltage, Rated control voltage at DC, minimum
20.4 VDC
Electrical data, Input signal, HIGH Signal "1"
10 … 30 VDC
Electrical data, Input signal, LOW Signal "0"
0 … 2 VDC
Electrical data, Input resistance at GND
4000 Ω
Hinweis, Delivery capacity
Phased-out product
Note, ISD, Fault
Failure of the safety relay to pull-in or drop-out
Fault on the input circuits or the relay control circuits of
Interruption of the connections to the inductive proximity s
Failure of the proximity switches
Failure of one channel being evaluated
Note, ISD, General, Fehler
The following faults are registered by the safety monitoring
Web, Delivery notice (date until)
2023-12-31
Electrical data, Cable section, minimum
0.2 mm²
Type of Execution, Degree of pollution VDE 0110
2
Number, Signalling outputs
2
Power, electrical consumption, maximum
5 W
Safety parameters, Category, EN ISO 13849
3
Safety parameters, Mission time
20 Year(s)
Safety parameters, Performance Level,
d
Safety values, PFD value
0.0000001 /h
Number, semi-conductor outputs with signalling function, undelayed